Twin wall gas heating system designed for cost-effective venting of residential and small commercial atmospheric gas appliances with
input up to 60kw. It is suitable for both internal and external use, either as a complete system or in combination with masonry, i.e. flue blocks
or brick chimneys.
Note that BS 5440-1 requires the use of a stainless steel insulated flue on external runs exceeding 3 metres. K Vent fulfills this requirement and
is fully interchangeable with the B Vent range.
■ Twist-lock bayonet jointing system.
■ No locking bands required.
■ Aluminium inner liner and aluzink outer case
which can be painted if required.
■ 12.5 mm air gap between case and liner keep
case temperature low.
■ 0-90° adjustable bend.
■ When joint is made, the liner covers the
jointing collar, shielding it and permitting
easy drain-down of any moisture in the flue.
Debris Plate
Internal systems should be supported by using a support assembly
fixed on top of the first floor/ceiling joist. A Firestop plate is also
required fixed to the ceiling below. The clamp plate and firestop have
tags fixed to ensure 50mm distance to combustibles. In a normal
house, when passing through the second floor the only requirement
is two firestop plates because the system is adequately supported at
first floor level.
|